EWF1 is a wireless smoke detector; EWF1CO is a wireless carbon monoxide
(CO) detector combined with smoke detector. In case of smoke detecion or car-
bon monoxide level increase, EWF1/EWF1CO will indicate the alarm and noify
ELDES system about the event.
EWF1 est un détecteur de fumée radio; EWF1CO est un détecteur de mon-
oxyde de carbone (CO) radio. En cas d’augmentaion du niveau de fumée ou
de monoxyde de carbone, EWF1/EWF1CO va alerter le système Eldes de cet
événement.
EWF1 es un detector de humo inalámbrico; EWF1CO es un detector de monóx-
ido de carbono (CO) inalámbrico combinado con el detector de humo. En caso
de que se produzca la detección del aumento de humo o monóxido de carbo-
no, EWF1/EWF1CO indicará la alarma y noiicará al sistema ELDES sobre el
evento.
EWF1 é um detector fotoelétrico de fumaça sem ios; EWF1CO é um detector
fotoelétrico de fumaça e monóxido de carbono (CO) sem ios. Quando a con-
centração de fumaça/CO ultrapassa um determinado nível, EWF1/EWF1CO
acionará o alarme e noiicará o sistema ELDES quanto ao evento.
3
EWF1-EWF1CO
EN | FR | ES | PT
D
O
N
O
T
P
A
I
N
T
+ -
+ -
TEST
D
O
N
O
T
P
A
I
N
T
+ -
+ -
TEST
1 x 1 x 1 x
2 x
EN
Package Contents |
ES
Contenido del paquete
FR
Contenu du pack |
PT
Conteudo do Pakote
TEST
EN LED SIREN
TEST
WEEKLY BUTTON
TAMPER BATTERY RESET
FR LED SIRÈNE
BOUTON TEST
WEEKLY
ANTIARRACHEMENT PILE RÉINITIALISER
ES
LED
SIRENA
BOTÓN TEST
WEEKLY
TAMPER BATERÍA
BOTÓN DE
REINICIO
PT INDICADOR LED
SIRENE
INTERNA
BOTÃO TEST
WEEKLY
TAMPER BATERIA
BOTÃO PARA
RESET
4
EWF1-EWF1CO EN | FR | ES | PT
5
EWF1-EWF1CO
EN | FR | ES | PT
0,1 m
(0.33ft)
0,1 m
(0.33ft)
0,3 m
(0.99ft)
Max.
BEST HERE
MEILLEUR
EMPLACEMENT
MEJOR AQUÍ
MELHOR AQUI
0,9m
(2.95 ft)
0,9m
(2.95 ft)
METAL
MIN
+5°C(41°F)
MAX
+45°C (113°F)
MIN
+5°C(41°F)
MAX
+45°C (113°F)
MIN
+5°C(41°F)
MAX
+45°C (113°F)
METAL
MÉTAL
METAL
WHERE TO INSTALL
EN
FR
PT
ES
OÙ INSTALLER
DÓNDE INSTALAR
ONDE INSTALAR
6
EWF1-EWF1CO EN | FR | ES | PT
HOW TO INSTALL
EN
COMO INSTALAR
ES
COMMENT INSTALLER
FR
COMO INSTALAR
PT
2
1
1
2
2
1
1
2
2
1
1
2
7
EWF1-EWF1CO
EN | FR | ES | PT
2
1
1
2
3 MIN.
2
1
1
2
TEST
ELDES
Uility
WAIT FOR 3 MIN.
ATTENDRE 3 .
ESPERE POR 3 MIN.
AGUARDE 3 MIN.
PRESS FOR 2 SEC.
PRESSER PENDANT 2 SEC.
PRESIONE DURANTE 2 SEG.
PRESSIONE POR 2 SEG.
8
EWF1-EWF1CO EN
1. PLACEMENT
1. Place the detector as close as possible to the center of the ceiling. If not possible, mount no closer
than 10cm (0.33t) from a wall or corner. Also, if local codes allow, install the detectors on walls,
between 10 and 30cm (0.33 and 0.98t) from ceiling/wall intersecions.
2. Install a minimum of two units in every house, no mater how small the house is.
3. Place a detector in each room that is divided by a parial wall.
For best protecion we recommend that you install a detector in every room.
DO NOT place EWF1/EWF1CO in the following locaions:
 
hot water heaters). Use specialized detector with unwanted alarm control for this areas.
 
Install at least 3m (9.84t) away from these areas.
 
areas. The air could blow smoke away from the detector, interruping the alarm.
 
 -
tor operaion.
Incorrect placement will result in the decrease of operaional efeciveness.
EN
9
EWF1-EWF1CO
EN
2. WHAT SHOULD I KNOW
2.1 CARBON MONOXIDE CO POISONING
Carbon monoxide is a product of incomplete combusion of organic mater. It is a toxic
gas, but, being colorless, odorless, tasteless, and iniially non-irritaing, it is very dii-
cult for people to detect.
CONCENTRATION SYMPTOMS
35 ppm (0.0035%) Headache and dizziness within six to eight hours of
constant exposure
100 ppm (0.01%) Slight headache in two to three hours
200 ppm (0.02%) Slight headache within two to three hours; loss of
judgment
400 ppm (0.04%) Frontal headache within one to two hours
800 ppm (0.08%) Dizziness, nausea, and convulsions within 45 min; insen-
sible within 2 hours
1,600 ppm (0.16%) Headache, increased heart rate, dizziness, and nausea
within 20 min; death in less than 2 hours
ppm - Parts Per Million - is used to describe concentraions of contaminants in air.
In the event of ALARM caused by a criical CO concentraion level, keep calm and
carry out the following acions in the priority order:
 Open all windows and doors to increase the rate of venilaion.
 Turn of the appliances and stop using them where possible.
 Evacuate the building leaving the windows and doors open. You may re-enter the
property only when the alarm has stopped.
 Get immediate medical assistance for anyone sufering the efects of carbon mon-
oxide poisoning (nausea, headache), and report that carbon monoxide inhalaion is
suspected. Contact the gas or other fuel supplier on their emergency phone number
in order to idenify and eliminate the source of carbon monoxide emissions.
10
EWF1-EWF1CO EN
 Do not use the appliance again unil it has been veriied and conirmed by a compe-
tent person according to naional regulaions.
There could be other sources of carbon monoxide emissions. For example, large
amount of city gas, tobacco smoke or smoldering ire can cause CO concentra-
ion ALARM.
2.2 CO ALARM/RESTORE AND FAULT INDICATIONS
 - when CO concentraion is 0-29ppm. This level causes no alarm when reached
as well as it results in zone restore event when one of the criical levels has been reached and
decreased to 0-29ppm aterwards. The zone restore event is indicated by SMS text message
delivered to the listed user phone number and data message delivered to the monitoring staion
followed by silenced sirens. Also, data message noifying about CO gas fault is delivered to EL-
DES Cloud Services and added to the Event Log.
 – when CO concentraion of 30-49ppm remains for more than 120 minutes.
Indicated by fault indicaion displayed by EKB2 LCD keypad (only for ESIM364/ESIM384) and
a warning delivery to the listed user by SMS text message. This level causes no zone alarm
when reached as well as it results in zone restore event in case the CO concentraion of 300ppm
or more (criical level 4) has been reached and decreased to 30-49ppm aterwards. Also, data
messages noifying about CO criical level 1 and gas fault detecion are delivered to ELDES
Cloud Services and added to both Event Log and Fault Log respecively.
 – when CO concentraion of 50-99ppm remains for more than 60 minutes.
Indicated by a 2-second beep every 5 seconds, LED indicator lash, fault indicaion displayed by
EKB2 LCD keypad (only for ESIM364/ESIM384) and a warning delivered to the listed user by
SMS text message. This level causes no zone alarm when reached. Also, data messages noify-
ing about CO criical level 2 and gas fault detecion are delivered to ELDES Cloud Services and
added to both Event Log and Fault Log respecively.
 – when CO concentraion of 100-299ppm remains for more than 10 minutes.
Indicated by a 2-second beep every 5 seconds, LED indicator lash and fault indicaion displayed
11
EWF1-EWF1CO
EN
by EKB2 LCD keypad (only for ESIM364/ESIM384) and a warning delivered to the listed user by
SMS text message. This level causes no zone alarm when reached. Also, data messages noify-
ing about CO criical level 3 and gas fault detecion are delivered to ELDES Cloud Services and
added to both Event Log and Fault Log respecively.
  – when CO concentraion of 300ppm and more is reached. This level will
cause an alarm when reached resuling in the unit emiing a 2-second beep every 5 seconds
and LED indicator lash. Meanwhile the system will noify the listed user by SMS text message
and the monitoring staion as well as all wired and wireless sirens will emit a pulsaing sound
based on the Fire-type zone operaional descripion and acivate the interconnecion feature (by
default - enabled; see). All wired and wireless sirens can be silenced by
disarming the system. However, EWF1CO built-in siren will remain acive unil the TEST WEEK-
LY buton has been pressed. Also, data messages noifying about CO criical level 4 and gas fault
detecion are delivered to ELDES Cloud Services and added to both Event Log and Fault Log
respecively.
  – when CO sensor’s 7-year lifeime period has ended or in case of any technical
issue that has occurred. Indicated by a fault indicaion displayed by EKB2 LCD keypad (only for
ESIM364/ESIM384) and noiicaion delivery to the listed user via SMS text message and the
monitoring staion. Please contact your local suppli er for repair service.
 CLEANING AND PRECAUTIONS DURING USE
Clean the detector at least once a month to remove dust, dirt, or debris. Using the sot brush or
wand atachment of a vacuum cleaner, vacuum all sides and cover of the detector. Be sure all the
vents are free of debris. If necessary, use a damp cloth to clean the detector cover.
Some household substances can afect the sensiivity of the detectors in a short or long term. Avoid
the use of model paint, model glue or nail polish remover close to the detector. Do not use aerosol
sprays, household cleaners, polishes or perfumes close to the device.
Do not atempt to remove the cover to clean inside the detector. This will void your warranty.
12
EWF1-EWF1CO EN
 CONFIGURING AND PAIRING WITH THE SYSTEM
ELDES
Uility
For more details on how to conigure and pair the device with the system,
please refer to ELDES Uility sotware’s menu or to ELDES alarm system’s
installaion/user manual.
If you are unable to pair the wireless device, please restore the
parameters of the wireless device to default and try again (see
 for more details).
 MAINTENANCE
 TESTING THE UNIT
             
WEEKLY buton and the detector will sound a loud beep. The alarm will stop sounding ater re-
leasing the TEST WEEKLY buton. When tesing EWF1/EWF1CO using ELDES Uility sotware,
the detector will provide short beeps.
 
monoxide concentraion below 30ppm. The buton release will be followed by a built-in siren
sound ater a 10-second period:
 
 
 
 
household for several days.
 
 
 
sotware.
13
EWF1-EWF1CO
EN
Test all detectors weekly to ensure proper operaion.
CO self-test is possible only ater more than 3 minutes of EWF1CO runime.
 INTERCONNECTION
The interconnecion feature automaically links all wireless detectors that are paired with the alarm
system. When any EWF1/EWF1CO detects smoke/CO, it will sound the built-in siren and send the
signal to the alarm system resuling in an instant alarm followed by built-in siren sound caused by the
rest of EWF1/EWF1CO devices. EWF1/EWF1CO device that detected smoke will auto-reset when the
smoke clears, while the rest of EWF1/EWF1CO devices will coninue to sound in accordance with the set
ime period (by default - 30 seconds) that can be managed by ELDES Uility sotware.
Interconnecion will commence when CO criical level 4 has been reached (see 2.2. CO
Alarm/Restore and Fault Indicaions).

For more informaion on how to change the batery and perform a device test, see secion HOW TO
INSTALL on page 6-7.
Only Primary 9V Lithium 1200mAh batery can be used. Install only new, high quality and
unexpired bateries.
The batery must be removed if the device is not in use.
14
EWF1-EWF1CO EN
In order to avoid ire or explosion hazards, the system must be used only with approved bat-
tery. Special care must be taken when connecing posiive and negaive batery terminals.
Dispose old bateries only into special collecion sites. Do not charge, disassemble, heat or
incinerate old bateries.
The batery status can be monitored in real-ime using ELDES Uility sotware.
The system sends an SMS message to the listed user phone number as soon as the batery
level runs below 5%.
We strongly recommend using EVE CR9V-P, Energizer LA522 or Ultralife U9VL-J 6F22
batery.

1. Remove the batery from EWF1/EWF1CO.
2. Press and hold the RESET buton.
3. Insert the batery back to EWF1/EWF1CO.
4. Hold the RESET buton unil you hear a short beep.
5. Release the RESET buton.
5. EWF1/EWF1CO ZONE AND TAMPER
Upon successful device pairing process, the system adds wireless zone (-s) as follows:
  - 1 Fire-type zone intended for smouldering ire/smoke detecion.
  - 1 Fire-type and 1 CO-type zone intended for smouldering ire/smoke detecion and
carbon monoxide detecion respecively.
In case of tamper violaion, the alarm is caused regardless of system being armed or disarmed.
There are 2 ways to detect tamper violaion on EWF1/EWF1CO:
15
EWF1-EWF1CO
EN
  EWF1/EWF1CO comes equipped with a built-in tamper switch intended for
enclosure supervision: The tamper switch is located on the back of the PCB supervising the
back side of the enclosure in case the device is illegally detached.
Once the enclosure of EWF1/EWF1CO is tampered with, the tamper switch will become trig-
gered. This acion will be followed by an alarm, resuling in sending an SMS text message and/
or phone call to the user. The SMS text message contains the violated tamper name. Also, this
event is added to the Event Log, meanwhile data messages noifying about triggered tamper
are delivered to the Monitoring Staion and ELDES Cloud Services respecively.
  The wireless connecion loss between EWF1/EWF1CO and ELDES
alarm system leads to alarm. The system ideniies this event as a tamper violaion and sends
alarm by SMS text message and phone call to the user (-s) by default. The SMS text message
contains the wireless device model, wireless ID code and tamper name. The user will also be
noiied by SMS text message as soon as the wireless signal is restored. Also, this event is added
to the Event Log, meanwhile data messages noifying about wireless connecion loss will be
delivered to the Monitoring Staion and ELDES Cloud Services respecively.
The tamper will not operate if the wireless zone (-s) is disabled.
6. TEMPERATURE SENSOR
The device comes equipped with a built-in temperature sensor allowing to monitor the temperature
of the area surrounding EWF1/EWF1CO device. When using the with EPIR3 alarm system, you may
-
sage delivery to the listed user phone number once exceeded. The accuracy of temperature measure-

exceeded temperature threshold are delivered to the Monitoring Staion and ELDES Cloud Services
respecively.
16
EWF1-EWF1CO EN
7. TECHNICAL SPECIFICATIONS
EWF1 compaible with:
 
 ESIM364 v02.04.01 and up.
 EPIR2 v01.01.02 and up.
 EPIR3 all versions.
 PITBULL ALARM all versions.
 PITBULL ALARM PRO all versions.
 ESIM384 all versions.
EWF1CO compaible with:
 ESIM364 v02.11.00 and up.
 EPIR3 v01.07.00 and up.
 PITBULL ALARM V02.01.00 and up.
 PITBULL ALARM PRO all versions.
 ESIM384 all versions.
Main features
 Photoelectric sensor for slow smouldering ires
(EWF1) / Combined photoelectric and electro-
chemical sensor for slow smouldering ires and
carbon monoxide (CO) detecion (EWF1CO)
 TEST WEEKLY buton
 Non-radioacive technology for environmental
friendly
 High and stable sensiivity
 Quick ix mouning plate for easy
installaion
 LED operaion indicator
 Built-in speaker for audio alarm
indicaion
 Auto-reset when smoke clears
EWF1 is a wireless photoelectric-based smoke detector designed to detect smouldering ire before
bursing into lame, while EWF1CO is a wireless electrochemical-based carbon monoxide (CO) detec-
tor combined with photoelectric-based smoke detector designed to detect smouldering ire. When
the concentraion of smoke/CO exceeds a given threshold, the system will cause alarm, resuling
in built-in siren acivaion and SMS text message and phone call delivery (by default) to the listed
user’s phone number. By default, when more than one EWF1/EWF1CO device is used, the system will
automaically acivate the interconnecion fea ture. See 
ESIM264, EPIR2, EPIR3, PITBULL ALARM and PITBULL ALARM PRO alarm systems support up to
16 EWF1/EWF1CO devices, while ESIM364 and ESIM384 - up to 32 EWF1 devices. The maximum
wireless connecion range is 150m (492.13t) (in open areas).
17
EWF1-EWF1CO
EN
For complete informaion on device operaion with ELDES alarm system, please refer to EL-
DES alarm system installaion manual located at eldesalarms.com
ELECTRICAL & MECHANICAL CHARACTERISTICS
Batery .........................................................................Primary 9V Lithium 1604LC (ANSI/NEDA)
Number of bateries ................................................1
Batery operaion ime ...........................................18 months*
Wireless band ............................................................ISM868/ISM915
Wireless communicaion range ............................Up to 30m (98.43t) in premises; up to 150m (492.13t) in
open areas
Smoke detecion type .............................................Photoelectric chamber
Smoke sensiivity ....................................................3.0-6.0 % O bs/m
Carbon monoxide detecion type .........................Electrochemical
Carbon monoxide detecion range .......................0-400 ppm
Alarm sound level ...................................................85dB at 3m (85dB at 9.84t)
EWF1 lifeime ............................................................10 years
EWF1CO lifeime .......................................................7 years
Range of operaing temperatures . .......................
Humidity ....................................................................         
(non-condensing)
Dimensions ...............................................................110mm (4.33in) Ø
* The speciied operaion ime applies in case of no alarms and when having the device tested once a
week. The operaion ime might vary in diferent condiions.
Technical support
If you experience diiculty during the installaion or subsequent use of a ELDES UAB system, you may con-
tact ELDES UAB distributor or dealer in your country/region.
Warranty procedures
To obtain warranty service, you may return a defecive system to your original point of purchase, or the autho-
rized ELDES UAB dealer or distributor from whom you purchased the ELDES product.
18
EWF1-EWF1CO EN
Limited Liability
The buyer must agree that the system will reduce the
risk of ire, thet, burglary or other dangers but does
not guarantee against such events. ELDES UAB will
not take any responsibility regarding personal or prop-
erty or revenue loss while using the system. ELDES
UAB liability according to local laws does not exceed
value of the purchased system. ELDES UAB is not af-
iliated with any of the Internet providers therefore is
not responsible for the quality of Internet service.
Manufacturer Warranty
ELDES UAB warrants this system only to the original
purchaser and only in case of defecive workmanship and
materials under normal use of the system for a period of
twenty four (24) months from the date of shipment by
the ELDES UAB. Warranty obligaions do not cover
expandable materials (components, which require
periodic replacement with the operaion of system -
power elements (bateries)), holders and enclosures.
The warranty remains valid only if the system is used
as intended, following all guidelines outlined in this
manual and in accordance with the operaing condiions
speciied. The warranty is void if the system has been
exposed to mechanical impact, chemicals, high humidity,
luids, corrosive and hazardous environments or force
majeure factors.
Safety instrucions
Please read and follow these safety guidelines in order to
maintain safety of operators and people around:
      
with other devices and cause any potenial danger.
 
 
 -
ical environment or mechanical impacts.
 
Copyright © ELDES UAB, 2018.
All rights reserved
It is not allowed to copy and distribute informaion
in this document or pass to a third party without ad-
vanced writen authorizaion by ELDES UAB. ELDES
UAB reserves the right to update or modify this doc-
ument and/or related products without a warning.
Hereby, ELDES UAB declares that smoke, carbon
monoxide alarm EWF1/EWF1CO is in compliance
with the essenial requirements and other relevant
provisions of Direcive 1999/5/EC. The declaraion
of conformity may be consulted at eldesalarms.com
The WEEE (Waste Electrical and Electronic
Equipment) marking on this product (see let)
or its documentaion indicates that the product
must not be disposed of together with household
waste. To prevent possible harm to human health
and/or the environment, the product must be
disposed on in an approved and environmentally
safe recycling process. For further informaion on
how to dispose of this product correctly, contact
the system supplier, or the local authority respon-
sible for waste disposal in your area.
ELDES UAB,
Ukmerges st. 283B,
Vilnius, Lithuania
EN14604:2005
Smoke, carbon monoxide alarm
EWF1/EWF1CO
19
EWF1-EWF1CO
FR
1. EMPLACEMENT
1. Placer le détecteur sur le plafond aussi prêt que possible du centre de la pièce. Si ce nest pas
possible, le monter à plus de 10 cm (0.33t) d’un mur ou d’un angle. Aussi, si les autorités locales
l’accordent, vous pouvez installer l’appareil sur un mur entre 10 et 30cm (0.33 et 0.98t) du
plafond ou d’une intersecion de murs.
2. Installez au minimum 2 unités dans chaque maison, peu importe la taille de cete dernière.
3. Placez un détecteur dans toutes les pièces séparés par un mur.
Pour une protecion opimale, nous recommandons d’installer un détecteur dans toutes les
pièces.
NE PAS installer EWF1/EWF1CO dans les endroits suivants:
 
d’un four, près d’un chaufe eau). Uilisez un détecteur spécial avec contrôle d’alarmes intem-
pesives pour ces zones.
 
Installez l’appareil au moins à 3m de ces zones.
 
ces zones. L’air pourrait détourner la fumée loin du détecteur, ce qui empêcherait l’alerte.
 

 -
ionnement de l’appareil.
Un emplacement incorrect va diminuer leicacité de l’appareil.
FR
20
EWF1-EWF1CO FR
2. CE QUE JE DOIS SAVOIR
2.1 INTOXICATION AU MONOXYDE DE CARBONE (CO)
Le monoxyde de carbone est le produit d’une combusion organique incomplète. C’est
un gaz toxique qui est invisible,inodore, insipide et non irritant au début, qui est très
diicile de détecter.
CONCENTRATION SYMPTÔMES
35 ppm (0.0035%) Mal de tête et veriges après 6 à 8 heures d’exposiion
coninue
100 ppm (0.01%) Léger mal de tête en 2 à 3 heures
200 ppm (0.02%) Léger mal de tête dans les 2 à 3 heures; perte de discernement
400 ppm (0.04%) Mal de tête frontal après 2 ou 3 heures
800 ppm (0.08%) Veriges, nausées, et convulsions après 45mn; inconscient
dans les 2 heures
1,600 ppm (0.16%) Mal de tête, pulsion cardiaque accélérée, veriges et nausées
dans les 20 min; mort en moins de 2 heures
ppm – Parts par million - uilisé pour décrire la concentraion de l’air contaminé.
En cas d’alarme causée par un niveau de concentraion de CO criique, gardez votre
calme et suivez les instrucions suivantes dans lordre:
 Ouvrir toutes les fenêtres et les portes pour augmenter la venilaion.
 Éteindre tous les appareils et arrêter leur uilisaion.
 Evacuer le bâiment en laissant portes et fenêtres ouvertes. Vous pourrez rentrer de
nouveau une fois que l’alarme cesse.
 Obtenir un e assistance médicale immédiatement pour toutes les personnes soufrant
de maux de tête et de nausées en reportant la suspecion d’inhalaion de monoxyde de
carbone. Contactez votre fournisseur de gaz ou de fuel sur leur numéro d’urgence pour
ideniier et éliminer la source d’émissions de monoxyde de carbone.
 Ne pas uiliser une installaion avant qu’elle est été vériiée par une personne compé-
tente.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52

Eldes EWF1CO Manual do usuário

Categoria
Detectores de fumaça
Tipo
Manual do usuário