eCore3kW General safety instructions
19
!
WARNING!
• Only install the device in closed, well-ventilated rooms.
• Never install the device in rooms where materials that are fire hazards
are stored, or where combustible gas is present; the surface
temperature can reach 60 °C.
• Do not operate the device in systems with lead acid batteries. These
batteries give off explosive hydrogen gas that can be ignited by sparks
on electrical connections.
• Before starting the device, ensure that the power supply lines are dry.
!
CAUTION!
• Ensure that the device is standing firmly.
The device must be set up and fastened in such a way that it cannot tip
over or fall down.
• Make sure that the device is earthed.
• Make sure that the lead has a sufficient cross-section.
• Lay the cables so that they cannot be tripped over or damaged.
• Fasten the cables securely.
• Do not expose the device to a heat source (such as direct sunlight or
heating). Avoid additional heating of the device in this way.
A
NOTICE!
• If cables have to be fed through metal walls or other walls with sharp
edges, use ducts or bushings to prevent damage.
• Do not lay cables which are loose or bent next to electrically
conductive material (metal).
• Do not pull on the cables.
• Do not lay the 230 V mains cable and the 12 V DC cable in the same
duct.
• Set up the device in a dry location where it is protected against
splashing water.
• Protect the device against corrosive fumes and salty or moist air.
• Protect the device and the cable against rain and moisture.
• Ensure good ventilation.
• Only install the device indoors, never outside.
• Do not connect the 230 V output of the inverter to a different 230 V
source.
eCore-3kW--I--WEST.book Seite 19 Donnerstag, 4. August 2016 11:53 11